Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Rev. estomatol. Hered ; 33(1): 18-25, ene. 2023. tab
Artigo em Inglês | LILACS, LIPECS | ID: biblio-1441862

RESUMO

Objective: To evaluate the microtensile bond strength in different dentine conditions (etched-E, non-etched-N, dry-D and wet-W) of a multimode adhesive (Scotchbond Universal-SU, 3M/ESPE) and a total etching adhesive (Ambar-AB, FGM) using a sonic device (Smart Sonic Device-SD, FGM). Material and methods: In this in vitro study, ninety six sound extracted human molars were divided into 12 groups (n=8) according to different dentine conditions and adhesive systems. Enamel was removed and the middle dentine surfaces were polished. Each adhesive system was applied according to the different dentine conditions, and composite resin blocks were incrementally built up and stored for 24 hours. Specimens were sectioned into sticks and bond strength data were analyzed with the Kruskal-Wallis test and Mann-Whitney U tests. Results: No effects of sonic application and were observed. In general, AB showed lower results compared to the SU. E and N conditions did not statistically affect the bond strength of SU groups. Dry dentine presented statistically superior bond strength values when compared to wet dentine for SU/E/SD group. Conclusion: Adhesion of dry dentine with multimode adhesive system may be superior to wet dentine with sonic application. The modes of application had no influence in bond strength of studied adhesives.


Objetivo: Evaluar la resistencia de la unión microtensil en diferentes condiciones de dentina (grabado-E, sin grabado-N, seco-D y húmedo-W) de un adhesivo multimodo (Scotchbond Universal-SU, 3M/ESPE) y un adhesivo de grabado total (Ambar-AB, FGM) utilizando un dispositivo sónico (Smart Sonic Device-SD, FGM). Material y Métodos: En este estudio in vitro, noventa y seis molares humanos extraídos sanos se dividieron en 12 grupos (n=8) de acuerdo con diferentes condiciones de dentina y sistemas adhesivos. Se eliminó el esmalte y se pulieron las superficies centrales de la dentina. Cada sistema adhesivo se aplicó de acuerdo con las diferentes condiciones de dentina, y los bloques de resina compuesta se acumularon de forma incremental y se almacenaron durante 24h. Las muestras se seccionaron en barras y los datos de resistencia de la unión se analizaron con la prueba de Kruskal-Wallis y la prueba de U de Mann-Whitney. Resultado: No se observaron efectos de la aplicación sónica. En general, AB mostró resultados más bajos en comparación con el SU. Las condiciones E y N no afectaron estadísticamente la fuerza de unión de los grupos SU. La dentina seca presentó valores de fuerza de adhesión estadísticamente superiores en comparación con la dentina húmeda para el grupo SU/E/SD. Conclusión: La adhesión de la dentina seca con un sistema adhesivo multimodo puede ser superior a la dentina húmeda con aplicación sónica. Los modos de aplicación no tuvieron influencia en la resistencia de la unión de los adhesivos estudiados.


Assuntos
Humanos , Resistência à Tração , Adesivos Dentinários , Dentina , Ultrassom , Técnicas In Vitro
2.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1535286

RESUMO

Introducción: la cerámica de disilicato de litio es una excelente opción en rehabilitación, confeccionado con la técnica de inyección o maquinadas. El objetivo de este estudio fue evaluar la influencia de dos sistemas adhesivos sobre los valores de resistencia de unión en cerámicas de disilicato de litio inyectado y maquinado. Métodos: se utilizó discos de disilicato de litio, IPS e. Max CAD (Ivoclar Vivadent, Liechtenstein, Swiss), de 10mm de diámetro y 1mm de espesor embebidos en tubos de PVC. Se distribuyó en 4 grupos de trabajo, 2 en cerámica de litio inyectadas y 2 en maquinada, se aplicaron los adhesivos Palfique Bond y Tetric N-bond Universal según la distribución de grupos, luego se fotopolimerizó durante 10 segundos con lámpara luz led, se colocaron los tubos Tygon® para el relleno con resina fluida; una vez retirado los tubos Tygon®, se llevaron las muestras a una máquina de ensayo universal donde se realizó la prueba de micro cizallamiento. Resultados: los valores de resistencia de unión más significativos fueron encontrados en las cerámicas de disilicato de litio adherida con el adhesivo Palfique Bond y Tetric Bond teniendo una diferencia significativa (p= 0.001), los valores de resistencia de unión del adhesivo Palfique Bond y Tetric Bond en cerámica inyectada no tuvieron diferencia significativa. Conclusión: las cerámicas de disilicato de litio maquinadas presentan mejores valores de resistencia de unión al micro cizallamiento.


Introduction: lithium disilicate ceramics are an excellent choice in rehabilitation, made with the technique of injection or machining. The aim of this study was to evaluate the influence of two adhesive systems on the values of binding resistance in injected and machined lithium disilicate ceramics. Methods: lithium disilicate disks, IPS e. were used Max CAD (Ivoclar Vivadent, Liechtenstein, Swiss), 10mm in diameter and 1mm in thickness embedded in PVC tubes. Was distributed in 4 working groups, 2 in injected lithium ceramics and 2 in machined, Palfique Bond and Tetric N-bond Universal adhesives were applied according to the group distribution, then photopolymerized for 10 seconds with led light bulb, Tygon® tubes were placed for filling with fluid resin; once the Tygon® tubes were removed. The samples were taken to a universal testing machine where the micro-spraying test was performed. Results: the most significant binding resistance values were found in lithium disisilicate ceramics adhered with the Palfique Bond and Tetric Bond adhesive having a significant difference (p= 0,001), the bond strength values of the Palfique Bond and Tetric Bond adhesive in injected ceramic did not differ significantly. Conclusion: machined lithium disilicate ceramics have better values of binding resistance to micro-spraying.

3.
Rev. bras. med. esporte ; 27(2): 207-211, Apr.-June 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1280070

RESUMO

ABSTRACT Introduction: Ischemic preconditioning (IPC) has been described in the literature as a resource capable of improving physical performance. Objective: The purpose of this randomized double-blind study was to evaluate the influence of IPC on the neuromuscular performance of trained individuals. Methods: Twenty-four (24) resistance training participants (6 of them women) with a mean age of 25.8 ± 4.6 years were selected and divided into two groups: the upper limb group (ULG) composed of 12 individuals (4 women) and the lower limb group (LLG) composed of 12 individuals (2 women). The maximum repetitions test was applied in the bench press for the ULG and in the 45° leg press for the LLG, with 50% of the one-repetition maximum under control, placebo and IPC conditions, at a random interval of 72 hours between tests. The IPC was applied four hours before the tests by means of an analog sphygmomanometer cuff inflated to 220 mmHg on the arm for the ULG and on the thigh for LLG, with three cycles of five minutes each of ischemia and reperfusion, alternating between the right and left sides. For the placebo, the cuff was inflated to 40 mmHg without causing ischemia. The significance level for the Wilcoxon test was p <0.017, due to the Bonferroni correction. The effect size (ES) was also analyzed. Results: With IPC, the ULG performed 34.8 ± 4.8 repetitions, representing an improvement of 11.29% (IPC vs. control, ES = 0.68 and p = 0.002) and the LLG performed 40.5 ± 15.7 repetitions, representing an improvement of 37.47% (IPC vs. control, ES = 0.84 and p = 0.002). No significant improvements were observed for the placebo in either group. Conclusion: Our data showed that IPC positively influenced neuromuscular performance of both the upper and lower limbs. Level of evidence II; Therapeutic studies investigating the results of treatment (Prospectived comparative studye).


RESUMEN Introducción: El preacondicionamiento isquémico (PCI) ha sido descrito en la literatura como un recurso capaz de mejorar el desempeño físico. Objetivo: El objetivo de este estudio aleatorio doble ciego fue evaluar la influencia del PCI en el desempeño neuromuscular de individuos entrenados. Métodos: Fueron seleccionados 24 individuos (6 mujeres) con promedio de edad de 25,8 ± 4,6 años, practicantes de entrenamiento resistido, divididos en dos grupos, siendo un grupo de miembros superiores (GMS) compuesto por 12 individuos (4 mujeres) y grupo de miembros inferiores (GMI) compuesto por 12 individuos (2 mujeres). El test de repeticiones máximas fue aplicado en el ejercicio de supino para el GMS y en el leg press 45° para el GMI con 50% de una repetición máxima, en las condiciones de control, placebo y PCI, de forma aleatoria con intervalo de 72 horas entre los tests. El PCI fue aplicado cuatro horas antes de los tests mediante un manguito de esfigmomanómetro analógico inflado a 220 mmHg en el brazo para el GMS y en el muslo para el GMI, siendo tres ciclos de cinco minutos de isquemia y cinco minutos de reperfusión, alternando los lados derecho e izquierdo. Para el placebo, el manguito quedó en 40 mmHg, sin provocar isquemia. El nivel de significancia del test de Wilcoxon fue p <0,017, debido a la corrección de Bonferroni. El tamaño del efecto (TE) también fue analizado. Resultados: Con el PCI, el GMS realizó 34,8 ± 4,8 repeticiones, representando mejora de 11,29% (PCI vs control, TE = 0,68 y p = 0,002) y el GMI realizó 40,5 ± 15,7 repeticiones, representando mejora de 37,47% (PCI vs control, TE = 0,84 y p = 0,002). Con el placebo, ambos grupos no mostraron mejora. Conclusión: Nuestros datos mostraron que el PCI influenció positivamente el desempeño neuromuscular tanto de miembros superiores como inferiores. Nivel de evidencia II; Estudios terapéuticos: investigación de los resultados del tratamiento (estudio comparativo prospectivo).


RESUMO Introdução: O pré-condicionamento isquêmico (PCI) tem sido descrito na literatura como um recurso capaz de melhorar o desempenho físico. Objetivo: O objetivo deste estudo randomizado duplo cego foi avaliar a influência do PCI no desempenho neuromuscular de indivíduos treinados. Métodos: Foram selecionados 24 indivíduos (6 mulheres) com média de idade de 25,8 ± 4,6 anos, praticantes de treinamento resistido, divididos em dois grupos, sendo um grupo de membros superiores (GMS), composto por 12 indivíduos (4 mulheres) e grupo de membros inferiores (GMI), composto por 12 indivíduos (2 mulheres). O teste de repetições máximas foi aplicado no exercício de supino para o GMS e no leg press 45° para o GMI com 50% de uma repetição máxima, nas condições de controle, placebo e PCI, de forma aleatória com intervalo de 72 horas entre os testes. O PCI foi aplicado quatro horas antes dos testes por meio de um manguito de esfigmomanômetro analógico inflado a 220 mmHg no braço para o GMS e na coxa para o GMI, sendo três ciclos de cinco minutos de isquemia e cinco minutos de reperfusão, alternando os lados direito e esquerdo. Para o placebo, o manguito ficou em 40 mmHg, sem provocar isquemia. O nível de significância do teste de Wilcoxon foi de p < 0,017, devido à correção de Bonferroni. O tamanho do efeito (TE) também foi analisado. Resultados: Com o PCI, o GMS realizou 34,8 ± 4,8 repetições, representando melhora de 11,29% (PCI vs. controle, TE = 0,68 e p = 0,002) e o GMI realizou 40,5 ± 15,7 repetições, representando melhora de 37,47% (PCI vs. controle, TE = 0,84 e p = 0,002). Com o placebo, ambos os grupos não apresentaram melhora. Conclusão: Nossos dados mostraram que o PCI influenciou positivamente o desempenho neuromuscular tanto de membros superiores quanto inferiores. Nível de evidência II; Estudos terapêuticos-Investigação dos resultados do tratamento (Estudo prospectivo comparativo).


Assuntos
Humanos , Masculino , Feminino , Adulto , Adulto Jovem , Precondicionamento Isquêmico , Força Muscular/fisiologia , Desempenho Atlético/fisiologia , Treino Aeróbico/métodos , Músculos/irrigação sanguínea , Resistência à Tração , Método Duplo-Cego , Teste de Esforço/métodos
4.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385764

RESUMO

ABSTRACT: This study aimed to evaluate possible changes in final retention after nine sequences of insertion and removal (SIR) of a frictional Morse taper implant/abutment system, evaluating the force required for dissociating this set between sequences, and verifying possible deformations in the implant heads. Ten implants, 13 mm long and 3.3 mm in diameter, were coupled to a universal mechanical testing machine. Ten anti-rotational abutments, 13 mm long and 3.5 mm in diameter, were connected to the implants parallel to the long axis, using an instrument called beat-connection, and subjected to tensile tests and SEM analysis. The results were analyzed using the Kruskal-Wallis test with Dunn's post-test, and the significance level was set at 5 %. There was no statistically significant difference in final retention among the nine SIRs evaluated. The force needed to uncouple the abutment from the implant increased as SIRs were performed on all ten implants, and an increase of 29.03 % was observed in the ninth SIR compared to the first SIR. After SEM analysis, no significant deformations, fractures, or cracks were observed in the implant heads.


RESUMEN: Este estudio tuvo como objetivo evaluar los posibles cambios en la retención final después de nueve secuencias de inserción y extracción (SIR) de un sistema de implante / pilar de cono de fricción Morse, evaluando la fuerza necesaria para disociar este conjunto entre secuencias y verificando posibles deformaciones en las cabezas de los implantes. Se acoplaron diez implantes, de 13 mm de largo y 3,3 mm de diámetro, a una máquina universal de ensayos mecánicos. Se conectaron a los implantes en paralelo al eje largo diez pilares antirrotacionales, de 13 mm de largo y 3,5 mm de diámetro, mediante un instrumento llamado beat-connection, y se sometieron a pruebas de tracción y análisis SEM. Los resultados se analizaron mediante la prueba de Kruskal-Wallis con la prueba posterior de Dunn, y el nivel de significancia se estableció en 5 %. No hubo diferencias estadísticamente significativas en la retención final entre los nueve SIR evaluados. La fuerza necesaria para desacoplar el pilar del implante aumentó a medida que se realizaban SIR en los diez implantes, y se observó un aumento del 29,03 % en el noveno SIR en comparación con el primer SIR. Después del análisis SEM, no se observaron deformaciones, fracturas o grietas significativas en las cabezas de los implantes.

5.
Rev. cuba. estomatol ; 57(4): e3076, Oct.-Dec. 2020. tab
Artigo em Português | LILACS, CUMED | ID: biblio-1144450

RESUMO

Resumo Introdução: Os pinos de fibra de vidro têm sido amplamente utilizados na reconstrução de elementos com perda excessiva de estrutura dentária. Objetivo: Avaliar a força de adesão de pinos de fibra de vidro após diferentes tratamentos radiculares em diferentes regiões (terço cervical, médio e apical) da dentina radicular. Métodos: Este é um estudo experimental in vitro. Quarenta dentes bovinos foram selecionados, preparados e distribuídos em quatro grupos de acordo com o tratamento de superfície utilizado: adesivo (1), agente quelante (2), ácido poliacrílico (3), não tratado (4). A cimentação dos pinos de fibra de vidro foi realizada com cimento resinosante autocondicionante. Após vinte dias, cada raiz foi cortada em três fatias (um milímetro de espessura) obtidas de três regiões. A resistência de união de cada seção foi determinada usando um teste de resistência da junta de encaixe. Os dados de resistência à flexão (MPa) foram analisados pelos testes ANOVA e Tukey (α = 0,05). Resultados: Na porção cervical, o grupo com tratamento prévio com ácido poliacrílico apresentou menor resistência ao cisalhamento por extrusão (push-out) do que o grupo sem tratamento prévio. O grupo com aplicação do sistema adesivo (28,89 ± 6,64 MPa) e o grupo com tratamento prévio com EDTA (21,58 ± 6,39 MPa) não apresentaram diferenças estatisticamente significantes em relação ao grupo sem tratamento prévio (grupo controle) no terço cervical. Nas porções média e apical, o grupo tratado com adesivo FGM Ambar apresentou maiores valores de ligação em comparação com os outros grupos. Conclusão: A aplicação prévia do adesivo aumentou a resistência de união nos terços médio e apical, em comparação aos outros grupos, podendo ter um efeito benéfico no sucesso clínico do tratamento restaurador(AU)


Resumen Introducción: Los postes de fibra de vidrio se han utilizado ampliamente en la reconstrucción de elementos con pérdida excesiva de estructura dental. Objetivo: Evaluar la fuerza de adhesión de postes de fibra de vidrio después de distintos tratamientos de raíz en diferentes regiones (tercios cervical, medio y apical) de dentina de raíz. Métodos: Estudio experimental in vitro. Se seleccionaron cuarenta dientes bovinos, se prepararon y se distribuyeron en cuatro grupos de acuerdo con el tratamiento de superficie utilizado: (1) adhesivo, (2) agente quelante, (3) ácido poliacrílico, (4) sin tratar. La cementación de los postes de fibra de vidrio se realizó con cemento de resina autograbante. Después de 20 días, cada raíz se seccionó transversalmente en tres rodajas (1 mm de espesor) obtenidas de tres regiones. La resistencia a la unión de cada sección se determinó usando una prueba de resistencia al corte por extrusión (push-out). Los datos de resistencia a la flexión (MPa) se analizaron mediante pruebas ANOVA y Tukey (α = 0,05). Resultados: En la porción cervical, el grupo con tratamiento previo de ácido poliacrílico mostró menor resistencia que el grupo sin tratamiento previo. El grupo con aplicación del sistema adhesivo (28,89 ± 6,64 MPa) y el grupo con tratamiento previo de EDTA (21,58 ± 6,39 MPa) no presentaron diferencias estadísticamente significativas en comparación con el grupo sin tratamiento previo (grupo control) en el tercio cervical. En las porciones media y apical, el grupo tratado con adhesivo Ambar® de FGM Dental Group mostró valores más altos de unión en comparación con los otros grupos. Conclusión: La aplicación previa del adhesivo aumentó la fuerza de unión en los tercios medio y apical, en comparación con los otros grupos, puede tener un efecto beneficioso sobre el éxito clínico del tratamiento restaurador(AU)


ABSTRACT Introduction: Glass fiber posts have been widely used for the reconstruction of elements with excessive dental structure loss. Objective: Evaluate the bond strength of glass fiber posts after various root dentin treatments in different regions (cervical, middle and apical thirds). Methods: An experimental in vitro study was conducted. Forty bovine teeth were selected, prepared and distributed into four groups according to the surface treatment used: (1) adhesive, (2) chelating agent, (3) polyacrylic acid, (4) not treated. The glass fiber posts were cemented with self-etch resin cement. After 20 days, each root was sectioned crosswise into three slices (1 mm in thickness) obtained from three regions. Bond strength was determined in each section with a push-out bond strength test. Flexural strength data (MPa) were analyzed with ANOVA and Tukey's tests. Results: In the cervical portion, the group with previous polyacrylic acid treatment displayed lower push-out strength than the group without previous treatment. The group with application of the adhesive system (28.89 ± 6.64 MPa) and the group with previous EDTA treatment (21.58 ± 6.39 MPa) did not exhibit any statistically significant differences in comparison with the group without previous treatment (control group) in the cervical third. In the middle and apical portions, the group treated with the adhesive Ambar® of FGM Dental Group showed higher bond values in comparison with the other groups. Conclusion: Previous adhesive application increased bond strength in the middle and apical thirds in comparison with the other groups, and may thus have a beneficial effect on the clinical success of the restorative treatment(AU)


Assuntos
Humanos , Reabsorção da Raiz/terapia , Preparo de Canal Radicular/métodos
6.
Coluna/Columna ; 19(3): 205-208, July-Sept. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1133584

RESUMO

ABSTRACT Objective To analyze the behavior of thoracolumbar fractures of the coronal split type using the finite element method. Methods Two comparative studies were conducted through simulation of coronal split fractures in a finite model in which the first lumbar vertebra (L1) was considered to be fractured. In the first case, the fracture line was considered to have occurred in the middle of the vertebral body (50%), while in the second model, the fracture line occurred in the anterior quarter of the vertebral body (25%). The maximum von Mises stress values were compared, as well as the axial displacement between fragments of the fractured vertebra. Results The stress levels found for the fracture located at half of the vertebral body were 43% higher (264.88 MPa x 151.16 MPa) than those for the fracture located at the anterior 25% of the vertebra, and the axial displacement of the 50% fractured body was also greater (1.19 mm x 1.10 mm). Conclusions Coronal split fractures located in the anterior quarter of the vertebral body incurred less stress and displacements and are more amenable to conservative treatment than 50% fractures occurring in the middle of the vertebral body. Level of Evidence III; Experimental study.


RESUMO Objetivo Analisar o comportamento das fraturas toracolombares do tipo split coronal através de elementos finitos. Métodos Foram realizados dois estudos comparativos através da simulação de fratura do tipo split coronal, em modelo finito, considerando que a primeira vértebra lombar (L1) estava fraturada. No primeiro caso, considerou-se que o traço da fratura ocorria na metade do corpo vertebral (50%), já no segundo modelo, o traço de fratura ocorria na porção anterior do corpo (25%). Foram comparados os valores de tensão máxima segundo von Mises, assim como o deslocamento axial sofrido entre os fragmentos da vértebra fraturada. Resultados Na fratura localizada ao nível da metade do corpo vertebral, os níveis de tensões encontrados foram 43% maiores (264,88 MPa x 151,16 MPa) do que aqueles na fratura a 25% no terço anterior do corpo vertebral, em que o deslocamento axial da porção fraturada também foi mais elevado (1,19 mm x 1,10 mm). Conclusões As fraturas do tipo split coronal localizadas no quarto anterior do corpo vertebral concentram menos tensões e deslocamentos, sendo mais passíveis de tratamento conservador em comparação às fraturas que ocorrem na metade do corpo vertebral. Nível de Evidência III; Estudo experimental.


RESUMEN Objetivo Analizar el comportamiento de las fracturas toracolumbares del tipo split coronal a través de elementos finitos. Métodos Se realizaron dos estudios comparativos a través de la simulación de fractura del tipo split coronal, en modelo finito, considerando que la primera vértebra lumbar (L1) estaba fracturada. En el primer caso, se consideró que el trazo de la fractura ocurría en la mitad del cuerpo vertebral (50%), ya en el segundo modelo, el trazo de la fractura ocurría en la porción anterior del cuerpo (25%). Fueron comparados los valores de tensión máxima según von Mises, así como el desplazamiento axial sufrido entre los fragmentos de la vértebra fracturada. Resultados En la fractura localizada al nivel de la mitad del cuerpo vertebral, los niveles de tensiones encontrados fueron 43% mayores (264,88 MPa x 151,16 MPa) que aquellos en la fractura a 25% en el tercio anterior del cuerpo vertebral, en que el desplazamiento axial de la porción fracturada fue también más elevado (1,19 mm x 1,10 mm). Conclusiones Las fracturas del tipo split coronal localizadas en el cuarto anterior del cuerpo vertebral concentran menores tensiones y desplazamientos, siendo más susceptibles de tratamiento conservador en comparación a las fracturas que ocurren en la mitad del cuerpo vertebral. Nivel de Evidencia III; Estudio experimental.


Assuntos
Humanos , Coluna Vertebral , Resistência à Tração , Fraturas da Coluna Vertebral
7.
Odontología (Ecuad.) ; 21(2): 19-38, 2019.
Artigo em Espanhol | LILACS | ID: biblio-1050031

RESUMO

Entre los requerimientos que debe cumplir una restauración provisional, destacan la adaptación marginal precisa y el sellado adecuado del agente cementante temporal. Objetivo: Comparar la adaptación marginal y resistencia a la tracción de coronas provisionales fabricadas con acrílico de termocurado y resina, cementadas con dos tipos de biomaterial. Me-todología: Estudio in vitro. 40 premolares superiores fueron tallados para recibir una corona completa que se confeccionó con dos tipos de biomaterial provisional (n=20): acrílico de termocurado Veracril® y resina Temp Basic® - CAD/CAM. Las coronas fueron cementadas con dos agentes cementantes temporales (Dycal® y TempBond NE®), se observó la adapta-ción marginal por medio de un estéreo microscopio; después, fueron sometidas a termociclado por 2.500 ciclos y luego se realizó una segunda observación y medición, finalmente se realizaron pruebas de tracción. Resultados: Mediante Kruskal Wallis se encontró diferencias significativas entre los grupos en ambos tiempos de estudio. Los grupos cementados con Dycal® presentaron mejor sellado marginal antes y después del termociclado y mayor resistencia a la tracción que los ce-mentados con TempBond NE® (p= <0,05). En todos los grupos la adaptación marginal fue menor después del termocicla-do (p= <0,05). Por medio del coeficiente de Pearson se determinó una correlación negativa (- 0.97) entre la desadaptación marginal y la resistencia a la tracción. Conclusiones: La desadaptación marginal tiene relación con el cemento utilizado, las coronas provisionales cementadas con Dycal® presentaron estadísticamente menor discrepancia marginal y mayores fuerzas de retención con relación al TempBond NE. El proceso de termociclado influyó en el aumento de la desadaptación marginal en todos los grupos. Cuando la desadaptación fue mayor disminuyó la resistencia a la tracción.


Among the requirements that must be carried out by a provisional restoration, the precise marginal adaptation and ade-quate sealing of the temporary cementing agent stand out. Objective: To compare the marginal adaptation and tensile strength of temporary crowns made of thermo-curing acrylic and resin, cemented with two types of biomaterial. Meth-odology: In vitro study. 40 upper premolars were carved to receive a complete crown that was made with two types of provisional biomaterial (n = 20): Veracril® thermosetting acrylic and Temp Basic® resin - CAD / CAM. The crowns were cemented with two temporary cementing agents (Dycal® and TempBond NE®), marginal adaptation was observed by means of a stereo microscope; then, they were subjected to thermocycling for 2,500 cycles and then a second observation and measurement was performed, finally tensile tests were performed. Results: Kruskal Wallis found significant differences between the groups in both study times. The groups cemented with Dycal® presented better marginal sealing before and after thermocycling and greater tensile strength than those cemented with TempBond NE® (p = <0.05). In all groups the marginal adaptation was lower after thermocycling (p = <0.05). By means of the Pearson coefficient, a negative correlation (- 0.97) was determined between marginal maladjustment and tensile strength. Conclusions: The marginal microleakage is related to the cement used, the provisional crowns cemented with Dycal® presented statistically lower marginal dis-crepancy and greater retention forces in relation to TempBond NE. The thermocycling process influenced the increase in marginal maladjustment in all groups. When the maladjustment was higher, the tensile strength decreased.


Entre os requisitos que uma restauração provisória deve atender, destacam-se a adaptação marginal precisa e o selamen-to adequado do agente de cimentação temporário. Objetivo: Comparar a adaptação marginal e resistência à tração de coroas temporárias de acrílico e resina de termopolimerização, cimentadas com dois tipos de biomateriais. Metodologia: Estudo in vitro. 40 pré-molares superiores foram preparados para receber uma coroa completa confeccionada com dois tipos de biomaterial provisório (n = 20): acrílico de termopolimerização Veracril® e resina Temp Basic® - CAD / CAM. As coroas foram cimentadas com dois agentes de cimentação temporários (Dycal® e TempBond NE®); a adaptação margi-nal foi observada por meio de estéreo microscópio; depois, foram submetidos a termociclagem por 2.500 ciclos térmicos e, em seguida, uma segunda observação e medição foi realizada; finalmente, testes de tração foram realizados. Resulta-dos: no teste Kruskal Wallis encontrou-se diferenças significativas entre os grupos nos dois tempos de estudo. Os grupos cimentados com Dycal® apresentaram melhor selamento marginal antes e depois da termociclagem e maior resistência à tração do que os cimentados com TempBond NE® (p = <0,05). Em todos os grupos, a adaptação marginal foi menor após da termociclagem (p = <0,05). Por meio do coeficiente de Pearson, foi determinada uma correlação negativa (- 0,97) entre discrepância marginal e resistência à tração. Conclusões: A perda da adaptação marginal está relacionada ao cimento utilizado, as coroas provisórias cimentadas com Dycal® apresentaram discrepância marginal menor estatisticamente significativa e maiores forças de retenção em relação ao TempBond® NE. O processo de termociclagem influenciou o au-mento da desadaptação marginal em todos os grupos. Quando a desadaptação foi maior, a resistência à tração diminuiu.


Assuntos
Adaptação Marginal Dentária , Cimentos Dentários , Restauração Dentária Temporária , Resistência à Tração , Materiais Biocompatíveis , Coroas
8.
Rev. Eugenio Espejo ; 11(1): 29-36, Jun.-2017.
Artigo em Espanhol | LILACS | ID: biblio-980822

RESUMO

Se desarrolló un estudio observacional comparativo, durante la cual se trabajó con toda la población estudio, la que estuvo constituida por 38 terceros molares sanos recolectados luego de extracción por causas odontológicas justificadas y con el consentimiento de los respecti-vos pacientes, cuyas edades oscilaron entre 20 y 25 años; la misma se distribuyó en dos grupo A (19) y grupo B (19); con el propósito de comparar la adherencia de la resina 3MZ250 en cavidades clase I de Black, utilizando dos tipos de fresas jota cilíndricas, de estas una de grano fino y otra grueso, en terceros molares in vitro. La investigación se desarrolló en cuatro etapas obteniendo los siguientes resultados: se estableció que en el grupo A, la adhesión de la resina a la estructura dentaria requirió una mayor fuerza de tracción promediando 215,49 N para desprenderla; mientras que en el B resultó de 167,7 N. El análisis estadístico mediante la prueba T permitió establecer que la diferencia de la resistencia a la tracción de la resina entre los grupos A y B resultó significativa. El uso de fresas de grano fino en la conformación de las cavidades clase I de Black crea paredes más lisas que permiten una mejor adhesión de la resina a la estructura dentaria; por lo que resultan más resistentes ante fuerzas de tracción.


A comparative observational study was carried out including the entire study population of 38 healthy third molars collected after extraction for medically justified reasons and with the consent of the respective patients. The ages ranged were from 20 to 25 years. It was distribu-ted in two strata: group A (19) and group B (19) in order to compare the adherence of resin 3MZ250 in class I GV Black cavities by using two types of cylindrical dental burs brand jota, the one of fine grained and the other thick, in third molars in vitro. The research was develo-ped in four stages obtaining the following results: in group A, the adhesion of the resin to the dental structure required a higher tensile force averaging 215.49 N to detach and in group B was 167.7 N. Statistical analysis using the T test allowed establishing that the difference in the tensile strength of the resin between groups A and B was significant. The use of dental burs of fine grained in the formation of class I GV Black cavities creates smoother walls that allow a better adhesion of the resin to the dental structure; so they are more resistant to tensile forces.


Assuntos
Humanos , Adulto , Resistência à Tração , Preparo da Cavidade Dentária , Cooperação e Adesão ao Tratamento , Doenças da Boca , Tratamento do Canal Radicular , Assistência Odontológica , Cimentos Dentários , Instrumentos Odontológicos
9.
Rev. bras. med. esporte ; 21(5): 332-337, tab, graf
Artigo em Inglês | LILACS | ID: lil-764644

RESUMO

ABSTRACTIntroduction:Both laser therapy and eccentric exercises are used in tendon injuries. However, the association of these physiotherapeutic modalities is yet little investigated.Objective:To evaluate the effect of low-level laser therapy associated to eccentric exercise (downhill walking) on Achilles tendinopathy of Wistar rats.Method:Eighteen Achilles tendon from 15 adult male Wistar rats were used. Tendons were distributed in six groups (laser, eccentric exercise, laser and eccentric exercise, rest, contralateral tendon, and healthy tendon). Unilateral tendinopathy was surgically induced by transversal compression followed by scarification of tendon fibers. The treatments laser therapy (904 nm, 3J/cm²) and/or eccentric exercise (downhill walking; 12 m/min; 50 min/day; 15o inclination treadmill) began 24 hours after surgery and remained for 20 days. Clinical and biomechanical analyzes were conducted. Achilles tendon was macroscopically evaluated and the transversal diameter measured. Euthanasia was performed 21 days after lesion induction. Tendons of both limbs were collected and frozen at -20°C until biomechanical analysis, on which the characteristic of maximum load (N), stress at ultimate (MPa) and maximum extension (mm) were analyzed.Results:Swelling was observed within 72 hours postoperative. No fibrous adhesions were observed nor increase in transversal diameter of tendons. Animals with the exercised tendons, but not treated with laser therapy, presented lower (p=0.0000) locomotor capacity. No difference occurred be-tween groups for the biomechanical characteristics maximum load (p=0.4379), stress at ultimate (p=0.4605) and maximum extension (p=0.3820) evaluated, even considering healthy and contralateral tendons.Conclusion:The concomitant use of low-level laser and the eccentric exercise of downhill walking, starting 24 hours after surgically induced tendinopathy, do not result in a tendon with the same biomechanical resistance or elasticity as a healthy tendon. On the other hand, it also does not influence negatively the structure and function of the Achilles tendon.


RESUMOIntrodução:Tanto a laserterapia como exercícios excêntricos são utilizados em lesões tendíneas. Entretanto, a asso-ciação dessas modalidades fisioterapêuticas ainda é pouco investigada.Objetivo:Avaliar o efeito da terapia com laser de baixa potência associada a exercício excêntrico (caminhada em declive) na tendinopatia do tendão calcanear de ratos Wistar.Método:Foram utilizados 18 tendões calcaneares provenientes de 15 ratos Wistar machos adultos. Os tendões foram distribuídos em seis grupos (laser, exercício excêntrico, laser e exercício excêntrico, repouso, tendão contralateral e tendão sadio). A tendinopatia unilateral foi cirurgicamente induzida mediante compressão transversal seguida pela escarificação das fibras tendíneas. Os tratamentos de laserterapia (904 nm, 3J/cm²) e/ou exercício excêntrico (caminhada em declive; 12 m/min; 50 min/dia; esteira com 15o de inclinação) se iniciaram 24 horas após a cirurgia e permaneceram por 20 dias. Foram conduzidas análises clínica e biomecânica. O tendão calcanear foi examinado macroscopicamente, e seu diâmetro transversal mensurado. Eutanásia foi realizada 21 dias após indução da lesão. Os tendões de ambos os membros foram obtidos e congelados a -20°C até realização da análise biomecânica, na qual foram testadas as características de carga máxima (N), tensão na carga (MPa) e extensão (mm) máxima.Resultados:Edema local foi observado nas primeiras 72 horas do pós-operatório. Não foram observadas aderências fibrosas, nem aumento no diâmetro transversal dos tendões. Animais com tendões exercitados, porém não tratados com laserterapia, apresenta-ram menor (p=0,0000) capacidade de locomoção. Não houve diferença entre grupos nas características biomecânicas de carga máxima (p=0,4379), tensão na carga (p=0,4605) e extensão máxima (p=0,3820), inclusive considerando-se tendões sadios e contralaterais.Conclusão:A utilização concomitante de laser de baixa potência e exercício excêntrico de caminhada em declive, iniciados 24 horas após tendinopatia induzida cirurgicamente, não resulta em um tendão biomecanicamente tão resistente ou elástico quanto um tendão saudável. Por outro lado, também não influencia negativamente na estrutura e função do tendão calcanear.


RESUMENIntroducción:Tanto la laserterapia como ejercicios excéntricos son utilizados en lesiones tendíneas. Entretanto, la asociación de esas modalidades fisioterapéuticas aún es poco investigada.Objetivo:Evaluar el efecto de la terapia con láser de baja potencia asociada a ejercicio excéntrico (caminata en declive) en la tendinopatía del tendón de Aquiles de ratas Wistar.Método:Fueron utilizados 18 tendones de Aquiles provenientes de 15 ratas Wistar machos adultos. Los tendones fueron distribuidos en seis grupos (láser, ejercicio excéntrico, láser y ejercicio excéntrico, reposo, tendón contralateral y tendón sano). La tendinopatía unilateral fue quirúrgicamente inducida mediante compre-sión transversal seguida por la escarificación de las fibras tendíneas. Los tratamientos de laserterapia (904 nm, 3J/ cm²) y/o ejercicio excéntrico (caminata en declive; 12 m/min; 50 min/día; cinta con 15o de inclinación) se iniciaron 24 horas después de la cirugía y permanecieron por 20 días. Fueron conducidos análisis clínico y biomecánico. El tendón de Aquiles fue examinado macroscópicamente, y su diámetro transversal medido. Fue realizada eutanasia 21 días después de la inducción de la lesión. Los tendones de ambos miembros fueron obtenidos y congelados a -20°C hasta la realización del análisis biomecánico, en el que fueron probadas las características de carga máxima (N), tensión en la carga (MPa) y extensión (mm) máxima.Resultados:Fue observado edema local en las primeras 72 horas del postoperatorio. No fueron observadas adherencias fibrosas, ni aumento en el diámetro transversal de los tendones. Los animales con tendones ejercitados, aunque no tratados con laserterapia, presentaron menor (p=0,0000) capacidad de locomoción. No hubo diferencia entre grupos en las características biomecánicas de carga máxima (p=0,4379), tensión en la carga (p=0,4605) y extensión máxima (p=0,3820), incluso considerándose tendones sanos y contralaterales.Conclusión:El uso concomitante de láser de baja potencia y ejercicio excéntrico de caminata en declive, iniciados 24 horas después de la tendinopatía inducida quirúrgicamente, no resulta en un tendón biome-cánicamente tan resistente o elástico cuanto un tendón sano. Por otro lado, tampoco influencia negativamente en la estructura y función del tendón de Aquiles.

10.
Rev. cient. odontol ; 3(1): 256-264, ene.-jun. 2015. ilus, tab
Artigo em Espanhol | LILACS, LIPECS | ID: biblio-1007351

RESUMO

OBJETIVO: Comparar la resistencia traccional de resina compuesta adherida a la superficie del esmalte de bovino en diferentes intervalos de tiempos de 15 y 30 segundos haciendo uso de ácido grabador en tres agentes cementantes autoadhesivos y un grupo control. MATERIALES Y MÉTODOS: Fueron utilizados treinta y cinco incisivos inferiores sanos de bovino menor de 3 años, los cuales fueron divididos aleatoriamente en siete grupos correspondientes a cada cemento autoadhesivo y tiempo de grabado ácido: RelyX U200 (3M) (grupo U15") (grupo U30"), Bis Cem (BISCO)(grupo B15")(grupo B30"), MaxCem Elite (KERR)(grupo M15")(grupo M30"), RelyX Ultimate (3M)(grupo UL) se procedió a la cementación con los bloques de resina compuesta como se indica el protocolo previo grabado ácido del esmalte de 15 y 30 segundos para cada cemento . Los especímenes de 1 mm2 de área transversal (n = 30 por grupo) se almacenaron en agua destilada por 24 horas a 36 °C. La prueba de microtensión se realizó haciendo uso del Microtensile Tester (Bisco). Para el análisis estadístico se utilizaron las pruebas de Kruskal Wallis y U Mann Whitney (p<0.05). RESULTADOS: El grupo U 30" presentó una resistencia promedio de 24.82 (±3.80) MPa; el U 15", 23.40 (±5.80 ) MPa, el M30",30.86 (±9.85) MPa, el M15", 28.29 (±2.02) MPa, el B 30", 17.42(±3.49) MPa, el B15",17.63 (±3.61) MPa, y el UL, 31.53 (±6.39 ) MPa, encontrando diferencia significativa entre ellos (p < 0.001) a través del análisis de Kruskal Wallis . CONCLUSIÓN: El cemento Relyx Ultimate obtuvo el valor más alto de resistencia traccional encontrándose diferencias estadísticamente significativas con todos cementos autoadhesivos. No se encontraron diferencias estadísticamente significativas al comparar los dos tiempos de grabado ácido de 15 y 30 seg. en esmalte entre los grupos de cementos autoadhesivos, al cabo de 24 horas. (AU)


OBJECTIVE: To compare the tensile strength of composite resin bonded to the surface of bovine enamel in different time intervals of 15 to 30 seconds using etchant in three adhesive cementing agents and a control group. MATERIALS AND METHODS: The study involved thirty-five healthy lower incisors lower calf of three years, which were rando-mly divided into seven groups corresponding to each adhesive cement and time of etching: RelyX U200 (3M) (U15 group ") (group U30 "), Bis Cem (BISCO) (B15 group") (B30 group "), Maxcem Elite (KERR) (M15 group") (M30 group "), RelyX Ultimate (3M) (UL group) proceeded to cementing with blocks Composite protocol as the previous etching enamel 15 and 30 seconds for each indicated cement. Specimens 1 mm2 cross-sectional area (n = 30 per group) were stored in distilled water for 24 hours at 36 ° C. Microtensile test was performed using the Microtensile Tester (Bisco). For statistical analysis, Kruskal Wallis and Mann Whitney U (p <0.05) were used. RESULTS: U 30 "group had an average strength of 24.82 (± 3.80) MPa; U 15 ", 23.40 (± 5.80) MPa, the M30", 30.86 (± 9.85) MPa, the M15 ", 28.29 (± 2.02) MPa, the B 30", 17.42 (± 3.49) MPa, B15 " 17.63 (± 3.61) MPa, and UL, 31.53 (± 6.39) MPa, finding significant difference between them (p <0.001) through the analysis of Kruskal Wallis. CONCLUSION: The Ultimate Relyx cement had the highest value of tensile strength found statistically significant differences with all adhesive cements. No statistically significant when comparing the acid etching time of 15 to 30 sec differences. between enamel adhesive cements groups, after 24 hours. (AU)


Assuntos
Animais , Bovinos , Resistência à Tração , Resinas Compostas , Cemento Dentário , Esmalte Dentário
11.
Rev. cient. odontol ; 3(1): 264-271, ene.-jun. 2015. ilus, tab
Artigo em Espanhol | LILACS, LIPECS | ID: biblio-1007420

RESUMO

OBJETIVO: Comparar in vitro la resistencia de unión entre dientes de bovino y cerámica feldespática utilizando los cementos fotoactivados para carillas (Choisse II, Variolink N, Relyx Ultimate).MATERIALES Y MÉTODOS: El grupo de estudio estuvo conformado por 3 grupos; un grupo control y 2 grupos experimentales distribuidos aleatoriamente y determinados mediante la fórmula para comparar promedios; con 120 especímenes en total, n= 30 especímenes por grupo; se utilizaron tres agentes cementantes: Relyx Ultimate (3M ESPE), Choise II (BISCO), Variolink N (IVOCLAR). Con los agentes autoadhesivos se procedió a la cementación como indica el protocolo para cada cemento. Los especímenes de 1 mm2 de área transversal, se obtuvieron con una máquina de cortes tipo IsoMet y se almacenaron en agua destilada por 24 horas a 36 °C. La prueba de microtensión se realizó haciendo uso del Microtensile Tester (Bisco). Para el análisis estadístico se utilizaron las pruebas de ANOVA y Tukey (p=0.05). RESULTADOS: El grupo Variolink N presentó una resistencia promedio de 18.42 ± 3,40 MPa; el Relyx Ultimate 18.42 ± 5,32 MPa, y el Choise II 11.92 ± 4,32 MPa, encontrando diferencia significativa entre ellos (p < 0.001) a través del análisis de ANOVA. CONCLUSIÓN: No existe diferencia significativa ente los cementos Variolink N y Relyx Ultimate, pero ambos fueron superiores significativamente al cemento Choisse II al cabo de 24 horas. (AU)


PURPOSE: To compare in vitro the bond strength between bovine teeth and feldespathic ceramic cements photoactivated using veneers (Choisse II, Variolink N, Relyx Ultimate).MATERIALS AND METHODS: The study group consisted of 3 groups; a control group and two experimental groups randomly distributed and determined by the formula for comparing averages; 120 total specimens, specimens n = 30 per group; Relyx Ultimate (3M ESPE), Choise II (BISCO), Variolink N (IVOCLAR): Three cementing agents were used. With adhesive agents proceeded to cementing as indicated by the protocol for each cement. Specimens 1 mm2 cross-sectional area, obtained with a cutting machine Isomet type and stored in distilled water for 24 hours at 36 ° C. Microtensile test was performed using the Microtensile Tester (Bisco). For statistical analysis, ANOVA and Tukey (p = 0.05) were used.RESULTS: Group Variolink N provided an average of 18.42 ± 3.40 resistance MPa; The Ultimate Relyx 18.42 ± 5.32 MPa, and 11.92 ± 4.32 Choise II MPa, finding significant difference between them (p <0.001) through the ANOVA analysis.CONCLUSION: There is no significant difference being cements and Relyx Variolink® N Ultimate, but both were significant-ly higher cement Choisse II after 24 hours. (AU)


Assuntos
Humanos , Resistência à Tração , Cemento Dentário , Esmalte Dentário
12.
Int. j. odontostomatol. (Print) ; 8(2): 261-266, set. 2014. ilus
Artigo em Inglês | LILACS | ID: lil-722898

RESUMO

The objective of this study was to evaluate the frictional resistance created in self-ligating esthetic and conventional brackets during simulated orthodontic sliding mechanics. Four different types of brackets were used: 3 self-ligating type of different brands (Clarity SL, 3M Unitek; Damon 3®, Ormco Corporation; In-Ovation C®, GAC International), in addition to conventional esthetic brackets (Radiance®, American Orthodontics) associated with conventional elastic ligatures (Sani-tie®, GAC International) and low friction ligatures (Slide®, Leone). To simulate sliding mechanics, stainless steel wires with thicknesses of 0.018" and 0.017"x0.025" (GAC International) were used. Five groups (n=10) were submitted to five consecutive mechanical tests in a universal test machine model Emic® DL 500. The results showed low frictional levels in all tested self-ligating brackets and with use of 0.018" wire (p<0.05). However, with 0.017x0.025" wire, Groups Damon 3, Clarity SL and Slide showed lower frictional forces when compared with In-Ovation C (p>0.05). Moreover, conventional esthetic brackets associated with conventional ligatures resulted in greater frictional resistance with both wires tested (p>0.05). All the self-ligating brackets presented lower frictional levels than the conventional accessories. Active self-ligating bracket In-Ovation C, demonstrated higher degree of frictional force when associated with rectangular wire. The Slide® ligature may be an alternative to the use of self-ligating brackets.


El objetivo fue evaluar la resistencia a la fricción producida en de brackets de autoligado estéticos y convencionales durante la simulación mecánica de deslizamiento ortodóncico. Se utilizaron cuatro tipos diferentes de soportes: 3 de tipo autoligado de diferentes marcas (Clarity SL, 3M Unitek; Damon 3®, Ormco Corporation; In-Ovation C®, GAC International), además de brackets estéticos convencionales (Radiance®, American Orthodontics) asociado con ligaduras elásticas convencionales (Sani-tie®, GAC International) y ligaduras de baja fricción (Slide®, Leone). Para simular la mecánica de deslizamiento, se utilizaron alambres de acero inoxidable con un espesor de 0,018" y 0,017"x0.025" (GAC Internacional). Cinco grupos (n = 10) fueron sometidos a cinco pruebas mecánicas consecutivas en una máquina de prueba universal modelo Emic DL ® 500. Los resultados mostraron niveles bajos de fricción en todos brackets de autoligado probados y con el uso de alambre de 0.018" (p<0,05). Sin embargo, con alambe de 0,017x0,025", los grupos Damon 3, Clarity SL y Slide® mostraron menores fuerzas de fricción en comparación con In-Ovation C (p>0,05). Por otra parte, los brackets estéticos convencionales asociados con ligaduras convencionales resultaron tener una mayor resistencia a la fricción con ambos alambres probados (p>0,05). Todos los brackets de autoligado presentan niveles de fricción más bajo que los accesorios convencionales. El brackets activo de autoligado In-Ovation C, demostró un mayor grado de fuerza friccional cuando se asocia con alambre rectangular. La ligadura Slide® puede ser una alternativa al uso de brackets de autoligado.

13.
Acta odontol. latinoam ; 25(2): 176-180, 2012. tab, ilus
Artigo em Inglês | LILACS | ID: lil-696313

RESUMO

Este estudio evaluó el efecto del almacenamiento en agua por 24 hs. (1d) y un año (1a) sobre la resistencia de unión de un adhesivo de grabadoácido independiene de dos pasos y un adhesivo autoacodicionante de dos pasos. Diez terceros molares fueron cortados perpendiculares a su eje longitudinal para exponer superficiesplanas de dentina. Los dientes fueron divididos en dos grupos según el adhesivo a ser usado: uno de acondicionamiento ácido independiente de dos pasos (Adper Single Bond 2) y uno autoacondicionante de dos pasos (Adper Scotchbond SE). Incrementosen resina compuesta (Z350) fueron construidas sobre las superficies tratadas con adhesivo. Los especimenes fueron cortados para obtener probetas (área de sección transversal = 0,8 mm2) y después de 1d y 1a de almacenamiento en agua destiladaa 37° C, fueron sometidas a la prueba de microtracción (1 mm/min). La captación de nitrato de plata en las interfaces fue analizada con microscopia electrónica de barrido (MEB). Los datos (MPa) fueron analizados con ANOVA de dos factores y la prueba de Bonferroni (p = 0,05). Después de 1d de almacenamiento SB2 presento los mayores valores de resistencia deunión. No hubo diferencias entre los adhesivos después de 1a, y para ASE estos valores fueron similares al tiempo 1d. Independientemente del tiempo de almacenamiento, ambos adhesivospresentaron captación de nitrato de plata dentro de la capa híbrida y la capa de adhesivo. Un año de almacenamiento en agua solo afectó los valores de resistencia de unión del adhesivo de grabado ácido independiente de dos pasos.


Assuntos
Humanos , Condicionamento Ácido do Dente , Adesivos Dentinários/química , Resistência à Tração , Teste de Materiais , Microscopia Eletrônica de Varredura , Dente Molar , Água
14.
Acta odontol. latinoam ; 25(2): 176-180, 2012. tab, ilus
Artigo em Inglês | BINACIS | ID: bin-128403

RESUMO

Este estudio evaluó el efecto del almacenamiento en agua por 24 hs. (1d) y un año (1a) sobre la resistencia de unión de un adhesivo de grabadoácido independiene de dos pasos y un adhesivo autoacodicionante de dos pasos. Diez terceros molares fueron cortados perpendiculares a su eje longitudinal para exponer superficiesplanas de dentina. Los dientes fueron divididos en dos grupos según el adhesivo a ser usado: uno de acondicionamiento ácido independiente de dos pasos (Adper Single Bond 2) y uno autoacondicionante de dos pasos (Adper Scotchbond SE). Incrementosen resina compuesta (Z350) fueron construidas sobre las superficies tratadas con adhesivo. Los especimenes fueron cortados para obtener probetas (área de sección transversal = 0,8 mm2) y después de 1d y 1a de almacenamiento en agua destiladaa 37° C, fueron sometidas a la prueba de microtracción (1 mm/min). La captación de nitrato de plata en las interfaces fue analizada con microscopia electrónica de barrido (MEB). Los datos (MPa) fueron analizados con ANOVA de dos factores y la prueba de Bonferroni (p = 0,05). Después de 1d de almacenamiento SB2 presento los mayores valores de resistencia deunión. No hubo diferencias entre los adhesivos después de 1a, y para ASE estos valores fueron similares al tiempo 1d. Independientemente del tiempo de almacenamiento, ambos adhesivospresentaron captación de nitrato de plata dentro de la capa híbrida y la capa de adhesivo. Un año de almacenamiento en agua solo afectó los valores de resistencia de unión del adhesivo de grabado ácido independiente de dos pasos.(AU)


Assuntos
Humanos , Adesivos Dentinários/química , Resistência à Tração , Condicionamento Ácido do Dente , Microscopia Eletrônica de Varredura , Água , Dente Molar , Teste de Materiais
15.
Acta odontol. venez ; 49(1)2011. tab
Artigo em Espanhol | LILACS | ID: lil-678862

RESUMO

Las tracciones orto-quirúrgicos son técnicas ampliamente utilizadas en odontología para la reposición en oclusión de dientes que incluidos. Nuestro objetivo fue evaluar la resistencia a la tracción de tres tipos de dispositivos de tracción. En este estudio in vitro fueron utilizados 45 premolares sanos, conservados inicialmente en suero fisiológico al 0,9%; fueron divididos en tres grupos, de los cuales 15 recibieron la instalación de brackets, 15 recibieron botones ortodóncicos y 15 recibieron la instalación de mallas. La adhesión fue realizada con resina de autocurado y en todos ellos se instaló un alambre ortodóncico de 0,30mm; los dientes fueron fijados con resina acrílica y almacenados en suero fisiológico al 0,9% por 72 horas. A continuación fueron sometidos a test de tracción mecánica, con una tracción máxima de 50N, siendo analizados con del programa Logger Pro®. Los brackets demostraron mayor resistencia a la tracción (44,6N), seguidos por los botones y finalmente por las mallas (32N). La principal área de falla fue la interface dispositivo/resina, siendo las mallas las que presentaron el mayor índice de fracaso (66%). Ningún alambre presentó ruptura en los análisis ejecutados. Las mallas presentan los resultados mecánicos más pobres cuando son comparados con botones y brackets; el área de ruptura más frecuente corresponde a la interface dispositivo/resina


Ortho-surgical tractions are techniques very used in dentistry for the reposition in occlusion of embedded teeth. The aim of this research was to evaluated the resistance to traction of three kind of devices used in a traction technique. In this in vitro research was used 45 bicuspid, initially maintained in saline solution (0,9%); were formed three groups, where 15 received brackets, 15 received button and 15 received mesh. The adhesion was do it with self-curing resin and in all of them was installed an orthodontics wire of 0,30 mm; the teeth was fixed with acrylic resin and maintained in saline solution (0,9%) for 72 hours. Follow that, the samples were submitted to mechanical traction test, with maximum traction of 50N, being analyzed with Logger Pro software. The brackets show more resistance to the traction (44,6N), follow that button and finally for mesh (32N). The principal areas of fracture was to device/resin interface, presented the mesh a more failure percentage (66%). Non wire presented fracture in the analyses. The mesh present poor results when compared to buttons and brackets; the more prevalent area failure was device/resin interface


Assuntos
Fios Ortodônticos , Técnicas In Vitro , Aparelhos Ortodônticos , Resistência à Tração , Ortodontia , Erupção Dentária
16.
Acta odontol. venez ; 49(4)2011. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-678883

RESUMO

Este estudio "in vitro" tuvo como objetivo evaluar a lo largo del tiempo (24 horas y 6 meses), el tratamiento del sustrato dentinario (desmineralización, desproteinización y antioxidante) y su influencia en la resistencia de la unión a la dentina, con tres adhesivos dentales. Noventa terceros molares humanos sanos recién extraídos se utilizaron: 72 para el ensayo de microtracción y 18 para análisis de interfaz en Microscopio electrónico de barrido (MEB). Estos fueron divididos aleatoriamente en tres grupos: AdperTM Scotchbond Multi-Uso (n=24); AdperTM Single Bond 2 (n=24); y XP Bond (n=24). Cada grupo fue dividido en 6 subgrupos (n = 4) de acuerdo con el tratamiento de la superficie dentinaria y el tiempo de evaluación. Sobre la zona de unión de todos los cuerpos de prueba se hizo un cilindro de 5 mm con resina compuesta FiltekTM Z250 (3M ESPE). Para el ensayo de microtracción se obtuvieron palillos (0,8 mm2). El análisis estadístico mostró que, a excepción del adhesivo XP Bond (65,07 ± 23,05), cuando se utilizó NaOCl, las otras medias fueron mayores en el tiempo de 6 meses que en 24 horas. El análisis del MEB mostró un patrón morfológico con capa híbrida uniforme y tags regulares. Considerando los resultados, se concluyó que la técnica con NaOCl dependió del sistema adhesivo y el tiempo, que la neutralización con el ascorbato de sodio revertió los valores obtenidos con NaOCl para ciertos grupos


This in vitro study investigated the influence of time (24h and 6 months) the treatment of the dentin substrate (demineralization, deproteinization, and antioxidant), and its influence on the bond strength using three dental adhesives. Ninety healthy human third molars freshly extracted were used for the microtensile test (n=72) and SEM analysis (n=18) randomly divided into three groups: AdperTM Scotchbond Multipurpose (n = 24); AdperTM Single Bond 2 (n = 24) and XP Bond (n = 24). Each group was further divided into 6 subgroups (n = 4) according to the treatment and evaluation time. A cylinder of 5mm was produced on the area of union using the composite resin Z250 (3M ESPE) and sticks of 0.8mm2 were obtained for the microtensile test. The statistical analysis showed that when NaOCl was used the average bond strength at 6 months was higher for most groups, except for XP Bond (60.48 ± 21.14 MPa). SEM analysis showed an uniform hybrid layer morphology and regular tags. Considering the results the effects of the NaOCl treatment on the bond strength was dependent on the adhesive system and time, and neutralization with sodium ascorbate reversed the values obtained with NaOCl for certain groups


Assuntos
Humanos , Cimentos Dentários/análise , Cimentos Dentários/uso terapêutico , Dentina , Hipoclorito de Sódio/análise , Hipoclorito de Sódio/uso terapêutico , Armazenamento de Materiais e Provisões , Resistência à Tração
17.
Acta odontol. venez ; 48(1): 45-50, mar. 2010. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-630246

RESUMO

El objetivo de este trabajo fue el de utilizar un colorante fluorescente y microscopio CLSM para observar la influencia de diferentes intensidades de luz en la resistencia de unión de un sistema adhesivo. Para tal fin, fueron creadas superficies planas en la dentina de 16 dientes terceros molares y divididos en 4 grupos: Grupo G1 - Foto-activador halógeno - KM-200R®; Grupo G2 - Foto-activador LED - Ultraled®; Grupo G3 - Foto-activador LED - UltraLume®LED5 y Grupo G4 - Foto-activador LED - Biolux Single V®. Para todos los grupos el procedimiento restaurador fue realizado utilizando el adhesivo Single Bond® pigmentado con rodamina B y la resina compuesta InTen-S®. Seguidamente, cada conjunto fue cortado, resultando en espécimen de aproximadamente 1 mm² de sección transversal, que luego fue seleccionado y llevado al test de micro-tracción para finalmente ser examinado con un microscopio digital y de CLSM. Los resultados mostraron luego de la evaluación estadística que el grupo 2 obtuvo valores medios de resistencia adhesiva significativamente menores que los demás grupos, que fueron semejantes entre si. Con relación al tipo de fractura, hubo diferencia entre los grupos G1 / G2 y entre los grupos G2 / G4; entre los otros grupos no hubo evidencia de diferencias significativas. Con esos resultados concluimos que la utilización de pigmentos fluorescentes y CLSM demostró ser una técnica simple y no destructiva, así también como la existencia de evidencias de que la intensidad de la luz foto-activadora influenció en la resistencia de unión en dentina.


The purpose of this study was to use a fluorescent dye and CLSM microscope to observe the effect of different light intensities on dentin tensile bond strength. Flat dentin surfaces were created on 16 intact human third molars and divided in 4 groups: Group G1 - halogen - KM -200R®; Group G2 - LED - Ultraled®; Group G3 - LED - UltraLume LED5® and Group G4 - LED - Biolux Single V®. For all the groups, the restoration procedure used Single Bond® adhesive, mixed with rodamin B and InTen-S® composite resin. Then, they were cut on serial sections to obtain 1 mm² area and submitted to micro tensile test and after words, the fractures were analyzed with a digital microscope and CLSM. The statistical analysis showed that all in all groups, except Group G2, which had a significant smaller tensile bond strength ratio. The fracture mode analysis showed that there were significant differences when comparing groups G1 / G2, and G2 / G4. There is no evidence of relevant differences among the other groups. With these results, we conclude that the use of fluorescent dye and CLSM demonstrated to be a simple and nondestructive technique, and that there are evidences that light intensities influenced the dentine tensile.

18.
Campinas; s.n; 2008. 49 p. ilus.
Tese em Português | BBO - Odontologia | ID: biblio-866531

RESUMO

Na busca por materiais mais resistentes, simples e de fácil aplicação, os fabricantes propõem e desenvolvem resinas e adesivos específicos para a colagem de braquetes, cada dia mais práticos e funcionais. O objetivo deste estudo foi avaliar a resistência ao cisalhamento de resinas compostas para colagem ortodôntica (No-etch Orthodontic Bonding - OrthoSource do Brasil; Fill Magic Ortodôntico - Vigodent). As resinas foram testadas de acordo com as recomendações do fabricante, e também, com aplicação de ácido fosfórico a 37% (FGM) e aplicação do adesivo multi-purpose (3M ESPE). Como grupo controle foi utilizado a resina Transbond XT (3M Unitek). Foram confeccionados 50 corpos de prova utilizando pré-molares extraídos com finalidades ortodônticas, incluídos em resina acrílica, acondicionada em tubos de pvc. Realizou-se a profilaxia com pedra pomes e água na face vestibular de cada elemento dentário previamente as colagens, separando os corpos de prova em cinco grupos (n=10), sendo o grupo I (controle): resina Transbond XT, seguindo as instruções do fabricante; grupo II: resina autocondicionante No-etch Orthodontic Bonding, seguindo as orientações do fabricante, sem o condicionamento com ácido fosfórico; grupo III: resina Fill Magic Ortodôntico, seguindo as orientações do fabricante, sem o uso de adesivo; grupo IV: resina No-etch Orthodontic Bonding, utilizando condicionamento ácido a 37% prévio; grupo V: resina Fill Magic, utilizando o adesivo scoth bond Multi-Purpose (3M ESPE). Todos os grupos foram fotopolimerizados por um período de 40 segundos cada, armazenados em água destilada a uma temperatura de 37° C, por 48 horas. Após este período realizou-se a aplicação da força de cisalhamento na interface braquete/resina, a uma velocidade de 0,5 mm/min. Os resultados foram submetidos ao teste de Kruskal-Wallis e de Mann-Whitney. Os valores apresentados pelas resinas Fill Magic Ortodôntico com média de 12,66 Mpa e No-etch Orthodontic Bonding com média de 7,38...


On the look out for more resistant and simple materials, manufacturers have presented and developed specific resins and adhesives that make brackets bonding more practical and functional. The aim of this study was to evaluate the resistance of composites resins self-etching adhesives to shear orthodontic bonding (No-etch orthodontic bonding-Ortho Source do Brasil; Fill Magic Orthodontic - Vigodent). The resins were tested following the manufacturer´s instructions, and with phosphoric acid application at 37% (FGM) and multi-purpose adhesive (3M ESPE). Transbond XT (3M Unitek) resin was used as control group. Fifty samples were made using pre molars extratect for orthodontic purposes, included in acrylic resin, disposed on pvc tube. Prophylaxis was carried out with pumice stone and water on the vestibular face of each dental element, previously to the bondings, and separating the samples in five groups (n=10), as follows group 1 (control): resin Transbond XT, following the manufacturer´s instructions; group 2: resin No-etch Orthodontic Bonding, following the manufacturer´s instructions, without the use of phosphoric acid etching; Group III: resin Fill Magic Orthodontic bonding, following the manufacturer´s instructions, without the use of adhesive; group IV: resin No-etch Orthodontic Bonding, using acid etching at 37%; and group V: resin Fill Magic Orthodontic, with adhesive scoth bond Multi-Purpose (3M ESPE). All groups were individualy light-cured for 40 seconds and stored in distilled water at 37° C for 48 hours. After this period, a shear power was applied to the bracket/resin interface, at a 0.5 mm/min speed. The results were submitted to Kruskal-Wallis and Mann-Whitney test. The resins Fill Magic with average about 12.66 Mpa and No-etch Orthodontic Bonding with average about 7.38 Mpa show statiscally relevant differences (p=0.0862) when compared to each other, but were significantly weaker (p<0.05) than the Fill Magic + adhesive (19.2 Mpa)... .


Assuntos
Adesivos Dentinários , Ortodontia , Resistência ao Cisalhamento , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...